Introduction
With the continuous demand for safe and sterile injection systems in the healthcare industry, starting a disposable syringe manufacturing business in the UK presents a high-potential opportunity. However, entering the UK medical device market requires more than just technical knowledge—it involves careful planning, regulatory compliance (particularly UKCA marking), and a clear understanding of the manufacturing process and equipment involved.
In this blog, we’ll walk you through everything you need to know to set up a disposable syringe manufacturing unit in the UK—from materials and machinery to quality systems and UKCA certification requirements.
Why Invest in Disposable Syringe Manufacturing?
The UK healthcare system depends heavily on single-use medical devices to reduce infection risk and improve patient safety.
Talk to our Experts
With growing demand in hospitals, clinics, and diagnostic labs, the market for disposable syringes in the UK remains robust. Factors driving this growth include:
- Rising demand for vaccines and injectable drugs
- Focus on infection prevention and control
- Increasing government emphasis on local manufacturing of medical devices
- Export opportunities across Europe and other regulated markets
Step-by-Step Process for Disposable Syringe Manufacturing
1. Raw Material Selection
The primary raw material used is medical-grade polypropylene (PP) for the barrel and rubber or synthetic elastomers for the plunger seal (gasket). Materials must be biocompatible and meet BS EN ISO 10993 standards for biological evaluation of medical devices.
2. Injection Moulding
This is the most critical stage where precision moulds are used to form the syringe components:
- Barrel Moulding
- Plunger (Piston) Moulding
- Needle Hub Moulding (if included)
High-speed injection moulding machines are used to ensure consistency, dimensional accuracy, and reduced cycle times.
3. Printing and Marking
Graduation markings and branding are printed on the barrel using automated syringe printing machines. These markings must comply with UK MDR 2002 labelling requirements and be durable, smudge-proof, and legible.
4. Assembly
Automated assembly machines are used to connect the barrel, plunger, and needle (if pre-attached) efficiently while maintaining sterility.
- Manual or semi-automatic systems can be used at small scale
- Fully automatic lines are ideal for large-scale production
5. Lubrication (Optional)
Food-grade silicone oil may be applied to the internal surface of the barrel to ensure smooth plunger movement.
6. Packaging
Syringes are individually packed in sterile blister packs or pouches using form-fill-seal machines or automated blister packaging lines. The packaging must meet UKCA requirements for sterility and labelling.
7. Sterilisation
Ethylene oxide (EtO) or gamma radiation are commonly used for sterilising syringes. The chosen method should comply with ISO 11135 or ISO 11137 standards respectively.
Key Machinery Required for Syringe Manufacturing
To ensure a consistent and high-quality product, your facility should include the following equipment:
| Machinery | Purpose |
|---|---|
| Injection Moulding Machine | Forming syringe components from plastic |
| Hot Runner Moulds | Precision moulds for barrel and plunger |
| Printing Machine | Graduations and brand name printing |
| Syringe Assembly Line | Assembling all parts of the syringe |
| Sterilisation Unit | EtO or Gamma sterilisation systems |
| Blister Packing Machine | Sterile packaging of syringes |
| Air Compressor and Chiller | Supporting equipment for moulding machines |
Facility Requirements and Cleanroom Standards
Disposable syringe manufacturing must be carried out in a controlled cleanroom environment, generally classified as ISO Class 8 (or equivalent to Grade D under EU GMP) to maintain particulate and microbial control.
You must also implement a Quality Management System (QMS) in line with ISO 13485:2016 and Good Manufacturing Practices (GMP).
Understanding UKCA Marking for Syringes
To legally market your disposable syringes in the UK, you must obtain UKCA certification (post-Brexit equivalent of CE marking). This involves:
- Device Classification: Syringes are generally Class IIa under UK MDR 2002.
- Conformity Assessment: For Class IIa devices, this requires involvement of a UK-approved conformity assessment body.
- Technical Documentation: Including device description, risk analysis, test reports, sterilisation validation, and packaging information.
- Label and IFU Compliance: All labelling must follow UK regulatory language and symbols as per applicable guidance.
- Registration with MHRA: All manufacturers must register their device and organisation with the UK’s Medicines and Healthcare products Regulatory Agency (MHRA).
Testing and Quality Checks
Before launch, each production batch must pass stringent quality checks:
- Leakage Test
- Plunger Movement and Force Test
- Graduation Accuracy
- Needle Bond Strength
- Sterility Testing
- Shelf-life Stability Studies
Planning to Enter the UK Syringe Market? Here's How We Can Help
Setting up a syringe manufacturing unit in the UK requires navigating technical, operational, and regulatory challenges. At Operon Strategist, we offer:
- Facility design as per cleanroom standards
- Machinery selection and layout planning
- ISO 13485 QMS implementation
- UKCA marking and MHRA registration support
- Product testing and sterilisation validation
- Regulatory consulting for market entry and documentation
Need expert guidance for UKCA certification or syringe manufacturing setup in the UK?
📞 Contact us today to book a consultation and take your first step toward entering the UK medical device market.